![]() Dinamap Pro 1000 MonitorProduct Details: MechanicalMonitor 12 in (H) x 4 in (D) x 14.5 in (W) 30.5 cm (H) x 36.8 cm (D) x 10.2 cm (W) Weight 12 lb (5450 gm) Environmental Operating Temperature: +41º F to +104º F (+5° C to +40° C) Storage Temperature -40º F to +158º F (-20º C to +60º C) Operating Humidity 5% to 95% noncondensing Storage Humidity 5% to 95% noncondensing Operating Atmospheric Pressure 700 hPa to 1060 hPa Storage Atmospheric Pressure 500 hPa to 1060 hPa Electrical AC Input Voltage 120 - 240 V AC Input Frequency 50 - 60 Hz AC Input Power 60 - 120 VA DC Input Voltage 18 - 24 V (supplied from a source conforming to IEC 601-1) DC Input Power 60 VA (supplied from a source conforming to IEC 601-1) Internal Battery 12 V nickel-metal-hydride (NiMH) Fuse (Battery) 10 A, 250 V Power Supply The PRO 1000 Monitor can be powered from the internal battery, AC power, or an external DC power source. Battery An internal, rechargeable battery pack powers the Monitor for 120 minutes (+/- 10 minutes)at a specified load. The battery typically charges to 90% capacity within 3 hours. Power Cable The 16-gauge power cable is detachable and measures 10 ft (3 meters) in length.
Method: Oscillometric step deflation, results equivalent to intraarterial
BP measurement
Modes: Manual, automatic, stat
b>BP Measurement Ranges:
Systolic 30 to 290 mmHg (adult)
30 to 140 mmHg (neonate)
MAP
20 to 260 mmHg (adult)
20 to 125 mmHg (neonate)
Diastolic
10 to 220 mmHg (adult)
10 to 110 mmHg (neonate
Resolution 1 mmHg
Accuracy Meets or exceeds AAMI/ANSI standard SP10
Initial Cuff Inflation Pressure 140 mmHg default; user selec table (adult)
110 mmHg default; user selectable (neo)
Maximum Determination Time 120 s (adult) 85 s (neonate)
Over Pressure Monitor 300 to 330 mmHg (adult)
150 to 165 mmHg (neonate)
Hose/Cuff Interface Clippard screw connectors at cuff end
Pulse Rate When NIBP is the source, HR values are derived
from the pulse rate that is determined by the oscillo-metric
technique of measuring blood pressure.
The rate source field is labeled NIBP.
Adult Range: 30 to 200 bpm (± 3.5%)
Neonate Range: 30 to 220 bpm (± 3.5%)
|
||||||||||||||
| Product | Description | Price |
|---|---|---|
![]() RFE-DP1000F |
Dinamap Pro 1000 - REFURBISHED You know the score. If your patients aren’t being sent home, then they require more care in the hospital than ever before. Basic vital signs just may not be enough. You could really use a monitor with simple ECG, too. [More Info] |
$5,352.00 [Buy] |
![]() FLA-DP1000-CTKN |
Dinamap Pro 1000 with Printer US versionGold Standard Care for Any SituationAnyone can detect normal blood pressure values. But where DINAMAP technology excels is in detecting the extremes, which are more difficult to determine and more critical to get right. There… [More Info] |
$13,380.00 [Buy] |
| GM-2014373001 |
Dinamap Pro monitors (100, 200,300, 400) rolling stand with pole mount clamp [More Info] |
$375.00 [Buy] |

Finger Pulse Oximeter
Hand-Held Pulse Oximeter
CPR Manikin
Zoll AED
New Ambulance
Ferno Stretchers
Used Stretchers Used Stair Chairs
Used Ambulance
Water-Jel
Stair Chairs
Dinamap Pro
Autovent
Capnographs
KED (Kendrick Extrication Device)
Blood Glucose Monitoring
Zoll M Series
Dash Monitors
Stethoscopes
Plastic Backboards
Cardiomedics
Zoll CTT
zoll Refubished Defibrillator
Refurbished Units
Holters
Blood Pressure Cuffs
Stryker Stretchers
Basket Stretcher
Stretcher Accessories
Scoop Stretcher
Oxygen Bags
Monitor/Equipment Carry Case
Ultra Series Bags
IV Pump
Ear/Eye Scope
Laryngoscopes
Suction Units
Hand-Held Suction Units
Rescue Stretchers
ACLS Manikin
Specialty Manikin
IV Manikin
Burn Care
FIrst Aid Kits
Mortuary Equipment
Rescue Equipment
Oxygen Ventilator
Flowmeter
Oxygen Regulator
Pediatric Transport
Whelen