BCI 6004-013 Mini-Torr Plus® NIBP / SpO2 / Electronic Thermometry .
BCI-6004013

BCI 6004-013 Mini-Torr Plus® NIBP / SpO2 / Electronic Thermometry .

This week only: Free UPS Ground shipping within continental
USA with your order of $250.00 or more!

$2,500.00
Product Description
The MINI-TORR PLUS� NON-INVASIVE BLOOD PRESSURE MONITOR provides a reliable platform for your NIBP monitoring needs. It easily adapts to meet your departmental NIBP needs, with options ranging from a lightweight roll stand or IV pole mount, to a built-in printer, pulse oximetry and Welch Allyn� SureTemp� temperature. Its combination of reliability and flexibility makes the Mini-Torr Plus� a practical starting point for your long-term NIBP monitoring needs. For more information visit smiths-bci.com.

SPECIFICATIONS:


Displays, Indicators & Keys:
  • SpO2 (Optional) 3-digit LED display, 0.40 inches (10.16 mm) high
  • Pulse Rate 3-digit LED display, 0.30 inches (7.62 mm) high
  • Pulse Strength Logarithmically scaled 10-segment
  • LED bar graph
  • NIBP 3-digit LED display
  • Systolic & Diastolic Pressures
  • 0.40 inches (10.16 mm) high
  • Mean Arterial Pressure
  • 0.30 inches (7.62 mm) high
  • Temperature 3-digit LED display, 0.40 inches (10.16 mm) high

  • NIBP:
  • Range Adult: 20 to 250 mmHg
  • Neonate: 20 to 135 mmHg
  • NIBP Accuracy Meets SP10-1992 AAMI standard for NIPB accuracy
  • Cuff Pressure �3 mmHg or 2%
  • Accuracy (whichever is greater)
  • Determination 30 to 50 seconds typical
  • Time (max. 120 seconds in adult mode, 90 seconds in neonate mode)
  • Interval Times 1, 2, 2.5, 5, 10, 15, 20, 30, 45, 60, 90 mins
  • Calibration Factory calibrated
  • Inflation Pressure Adult: 50 to 300 mmHg
  • Neonate: 50 to 150 mmHg
  • Default Inflation Adult: 175 mmHg
  • Pressure Neonate: 100 mmHg
  • Alarm Range
  • Adult High: 15 to 285 mmHg & OFF
  • (1 mmHg steps)
  • Low: 10 to 280 mmHg & OFF
  • (1 mmHg steps)
  • Neonate High: 15 to 135 mmHg & OFF
  • (1 mmHg steps)
  • Low: 10 to 130 mmHg & OFF
  • (1 mmHg steps)
  • Alarm Default
  • Adult Systolic: High - 200 mmHg
  • Low - 90 mmHg
  • Diastolic: High - 105 mmHg
  • Low - 40 mmHg
  • Mean Arterial: High - 140 mmHg
  • Low - 50 mmHg

  • Pulse Rate:
  • Range 30 to 180 bpm (NIBP) (adult)
  • 40 to 180 bpm (NIBP) (neonate)
  • 30 to 254 bpm (SpO2)
  • Accuracy �2% or 2 bpm (whichever is greater)
  • Alarm Range
  • Adult & Neonate High: 30 to 250 bpm & OFF (1bpm steps)
  • Low: 30 to 250 bpm & OFF (1bpm steps)
  • Alarm Default Adult: High: 150 bpm
  • Low: 45 bpm
  • Neonate: High: 150 bpm
  • Low: 50 bpm

  • SpO2 (Optional):
  • Range 0 to 100 SpO2 (functional)
  • Accuracy �2 counts at 70 to 100%
  • <70% unspecified
  • Averaging 8 beats
  • Pulse Tone Volume adjustable or OFF
  • (pitch corresponds to SpO2 value)
  • Alarm Default Adult: High: 150 bpm
  • Low: 45 bpm
  • Neonate: High: 150 bpm
  • Low: 50 bpm

  • Temperature (Optional):
  • Range 84�F to 108�F (28.9�C to 42.2�C)
  • Accuracy �2�F, ASTM E1112-86 (�0.1�C)
  • �3 counts at 50 to 69%
  • Calibration Factory calibrated

  • Dimensions:
  • Base Unit 3.24� H x 8.5� W x 5.5� D
  • 8.2 cm H x 21.6 cm W x 14.0 cm D
  • With Temp 3.24� H x 10� W x 5.5� D
  • 8.2 cm H x 25.4 cm W x 14.0 cm D

  • Weight:
  • Base Unit 3.5 pounds (1.6 kg)
  • With Temperature 4.2 pounds (1.9 kg)

  • AC Charger Power Requirements
  • 105 to 125 VAC, 60 Hz
  • 90 to 110 VAC, 50 Hz (optional); 230 VAC, 50/60 Hz (optional)
  • Output of 24VDC @ 1.5A with 4kV isolation

  • Battery Life
  • Nickel Cadmium battery, 6 VDC, internal rechargeable,
  • fully charged continuous-life 6 hours approximate, charge time 4 hours

  • Printer Output:
  • RS232C
  • Data Format: 19200 baud, 1 start bit, 8 data bits, 1 stop bit,
  • no parity

  • Integrated Printer (Optional):
  • Text only, no graphics. Patient data log or trend tables.

  • Environmental:
  • Operating Temperature:
  • Base Unit 32�F to 131�F (0�C to 55�C)
  • With Temperature 60.8�F to 104�F (16�C to 40�C)
  • Storage Temperature -40�F to 158�F (-40�C to 70�C)
  • Relative Humidity 10 to 95% (storage)
  • (non-condensing) 15 to 95% (operating)

  • Standards:
  • EN60601-1 (IEC60601-1), EN60601-1-1 (IEC60601-1-1)
  • UL 544, CSA Std. C22.2 No. 125-1984, EN60601-1-2 (IEC60601-1-2)

  • Regulatory Compliance:
  • 510(k): K983796, K984618, K970801
  • ISO 9001 / EN46001
  • Catalog Number: 6004
  • Related Products